Initial start-up
The original instructions require membranes to remain wet once wetted and the first hour’s permeate to be discarded.
PRODUCT DATA & TECHNICAL REFERENCE
Detailed reference data for membrane modules, selective layers and desalination systems. Figures are nominal or rated values from the original materials, rather than new test results.
MODULE DIMENSIONS & CONNECTIONS
| Model | Type | Effective membrane area | Length | Outer diameter | Connections | Housing | Net weight |
|---|---|---|---|---|---|---|---|
| CCM-cNF6010-2.5-uPVC | cNF | 2.5 m² | 555 mm | φ160 mm | DN32 adhesive connection | uPVC | 8 kg |
| CCM-cNF6020-4.5-uPVC | cNF | 4.5 m² | 755 mm | φ160 mm | DN32 adhesive connection | uPVC | 14 kg |
| CCM-cNF6040-09-uPVC | cNF | 9 m² | 1,255 mm | φ160 mm | DN32 adhesive connection | uPVC | 25 kg |
| CCM-cNF9040-25 | cNF | 25 m² | 1,488 mm | φ305 mm | Feed: DN100 flange; permeate: DN65 | SUS304 / 316L | 130 kg |
| CCM-cUF9040-16-uPVC | Ceramic UF | 16 m² | 1,480 mm | Not specified | Feed: DN100; permeate: DN50 clamp | uPVC | 50 kg |
Channels & installation:Original materials specify circular channels, φ1.6 mm, with vertical or horizontal installation and single-module or series operation.
Housing options:Materials list SUS304 / 316L / uPVC and illustrate SUS and FRP configurations. Confirm materials, connections and dimensions using the specific model drawing.
Selective layers:Original cNF materials list X=10 and X=90, with charged variants available for discussion. The cUF9040-16 is ceramic ultrafiltration; cNF selective-layer data do not apply to it.
SELECTIVE LAYER DATA
| Selective layer | Charge description | Pure-water test value | Rejection value | Operating pH | Temperature |
|---|---|---|---|---|---|
| X=10 | Near-neutral / negative | 40–50 LMH @ 1 bar | MgSO₄ approx. 10%; 6K dextran ≥95% | 3–10 | 5–75 °C |
| X=90 | Near-neutral / negative | 15–20 LMH @ 1 bar (original table: max 20) | MgSO₄ >80% (up to 95%); NaCl <10% | 3–10 | 5–75 °C |
| 90+ | Positive | 15–20 LMH @ 1 bar (original table: max 20) | MgCl₂ >80% (up to 95%); NaCl <10% | 3–10 | 5–75 °C |
| 90AB+ | Positive; described as acid/alkali resistant | 15–20 LMH @ 1 bar (original table: max 20) | CaCl₂ / MgCl₂ >90%; P element <10% (pH 1) | Original: Acid stable | Original: On request |
Original table footnote:1,000 ppm MgSO₄, 2 bar, 25 °C, 50% recovery; individual module permeate flow may vary by ±15%.
Matching conditions to results:These MgSO₄ conditions do not describe all pure-water, MgCl₂, CaCl₂, dextran or P-element tests. Each result requires its corresponding medium, method and conditions.
Pressure value requires clarification:The original table states “Maximum operating pressure >10 bar”. This does not specify an allowable upper limit and must not be used as an operating setpoint. Refer to the controlled model documentation.
Acid/alkali range:For 90AB+, “Acid stable” does not establish numerical pH limits, temperature limits or compatibility with every chemical medium.
START-UP · OPERATION · PRESERVATION
The original instructions require membranes to remain wet once wetted and the first hour’s permeate to be discarded.
Avoid permeate-side backpressure. Chemicals contacting the membrane must be within the permitted compatibility limits.
The original instructions specify the recommended preservation solution, followed by flushing and calibration before restart.
Reference summary only. Preservation chemicals, concentrations, durations, pressures and procedures must follow the model-specific operating documents and technical guidance.
DESALINATION SYSTEM DATA
Source: original system overview and SW24A / SW200 / SW500 pages. Values are rated at design feed conditions; the source package does not include the full design feed analysis.
| Parameter | Original specification |
|---|---|
| Configuration | Pretreatment + two-stage RO |
| Rated product flow | 1.0 m³/h |
| Rated feed flow | 2.7 m³/h |
| Rated specific energy | 6.6 kWh/m³ |
| Rated / installed power | 6.5 kW / 8 kW |
| Design pressure | High-pressure stage: 60 bar; low-pressure stage: 15 bar |
| RO elements | 11 × 4040 seawater elements |
| Dimensions (L × W × H) | 185 × 150 × 180 cm |
| Dry weight | 658 kg |
| Parameter | Original specification |
|---|---|
| Configuration | Pretreatment + two-stage RO |
| Rated feed flow | 25 m³/h |
| Rated power | 31.5 kW |
| Design pressure | High-pressure stage: 60 bar; low-pressure stage: 15 bar |
| RO elements | 16 × 4040 seawater elements; 4 pressure vessels (1,000 psi) |
| Dimensions (L × W × H) | 605 × 244 × 259 cm |
| Product flow / specific energy | Confirm against feedwater analysis |
| Parameter | Original specification |
|---|---|
| Configuration | Pretreatment + two-stage RO |
| Rated product flow | 25 m³/h |
| Rated feed flow | 60 m³/h |
| Rated power | 71 kW |
| Design pressure | High-pressure stage: 60 bar; low-pressure stage: 15 bar |
| RO elements | 42 × 4040 seawater elements; 7 pressure vessels (1,000 psi) |
| Specific energy | Confirm against feedwater analysis |
| Dimensions / dry weight | Not specified |
Confirm production and energy use against TDS, temperature, turbidity and system design. Unspecified values remain unspecified; model numbers are not used to infer capacity.
Process and pressure labels follow the original illustration. Site interfaces: seawater inlet, product outlet, concentrate outlet, cleaning-water inlet and raw-water tank inlet.
POWER OPTIONS
Evaluate power configurations around the energy resources and operating conditions at your site.
The original architecture connects solar PV, wind, energy storage and diesel backup to a DC 800 V bus, coordinated by an energy management system (EMS).
This is an optional architecture. It does not imply that every model includes all power equipment and functions as standard.
The original materials compare cNF with a UF + NF process using illustrative system-study figures. The package does not include the comparative designs, raw tests or calculation boundaries needed to treat these figures as project guarantees.
| Comparison | Change reported for cNF |
|---|---|
| System complexity | Approx. 50% simplification |
| Footprint | 30–40% reduction |
| Energy | 25–35% reduction |
| Operation & maintenance cost | 40–50% reduction |
UF–NF simplification, backwashing requirements and economics must be evaluated against feedwater, model selection, fouling, cleaning and engineering design.
Start with an existing water analysis or describe your project. Agree the next step before arranging any sample shipment.